Pond & Dock De-Icers for Canadian Winters
Kasco de-icers that keep water open around docks, boat lifts and shoreline structures through freeze-up. Half to one horsepower, three-year warranty, shipped across Canada.
- Authorized Kasco DealerFull factory warranty honoured
- Certified Repair CentreBench service in Markham, Ontario
- 50+ Years ExperienceServicing the GTA since 1974
- Ships Across CanadaMost orders out in 1-2 business days
We Are Proud to Partner With
Shop De-Icers by Horsepower
Horsepower decides how much open water you hold. Voltage decides which version of that model you order - it is not a plug swap.
The smallest de-icer in the range. Suited to a single dock, a boat lift or a modest pond where you need one area kept open through freeze-up. 120V, three-year warranty, supplied with 20 ft suspension ropes.
The most common choice on Ontario waterfronts. Same horsepower in both versions - the only difference is the supply voltage at your site. The H in 3400HD means 240V, not heavy duty.
The largest de-icer Kasco builds, for marinas, multi-slip docks and larger areas of open water. As above, the two versions differ only by supply voltage.
Alongside keeping water open, cold-water bacteria and fall treatments cut the organic load that causes winter fish kill under the ice. Dose before freeze-up for the best result.
Order before freeze-up, not after
De-icers sell out in October and the ice does not wait. Tell us what you are protecting and the voltage available at the dock, and we will spec the unit and cord length while there is still time to install it properly.
A De-Icer Does Not Melt Ice. It Stops Ice Forming.
The unit hangs below the surface and drives a column of warmer water up from below. Water at depth sits a few degrees above freezing all winter, and moving it upward keeps a patch of surface from setting. Nothing is being heated - the de-icer is simply refusing to let that water sit still long enough to freeze.
That mechanism decides where you point it. Aimed at a dock crib or a boat lift, it protects the structure from ice pressure, which is what causes most winter damage on Ontario waterfronts. Aimed into open water on a pond, it holds a hole that lets trapped gases escape from under the ice sheet, which is what prevents winterkill in a stocked pond.
Two things get ordered wrong. The first is voltage: the H in 3400HD and 4400HD indicates a 240V supply, not a tougher unit, and the horsepower is identical to the 120V version. The second is cord length, measured to the actual outlet rather than to the shore. Send us the dock layout and the supply and we will get both right. Planning further ahead? Read when to install a pond de-icer in Ontario.
-
HD means 240V, not heavy duty
A 3400HD is the same 3/4 HP as a 3400D. The H is the supply voltage. Check the panel at your dock before ordering.
-
Three-year warranty across the range
Every Kasco de-icer carries three years - a year longer than the equivalent surface aerator.
-
They hang, they do not float
Each unit ships with 20 ft of suspension rope. Mounting angle and depth control the shape of the opening you get.
-
Cord length is specced to the dock
Kasco builds cords from 25 ft to 200 ft. Measure from the unit to the outlet, not to the shoreline.
-
A thermostat panel pays for itself
Running only below a set water temperature cuts winter hydro considerably against running continuously.
Fifty Years. Thousands of Ontario Ponds.
Join the property managers, marina operators and cottage owners who call us first.
★4.8 out of 5 based on Google reviews›Buying guide
Questions our techs answer every autumn
De-icers get ordered in a hurry once the forecast turns. Here is what to settle first.
-
Voltage, and nothing else. Both are 3/4 HP. The 3400D runs on 120V and the 3400HD runs on 240V. The same applies to the 4400D and 4400HD at 1 HP.
The H does not stand for heavy duty and the HD models are not built for harsher conditions. Check the supply at your dock or shoreline outlet before ordering - it is a different unit, not a different plug.
-
It depends on how much open water you need to hold and how exposed the site is. The 1/2 HP 2400D suits a single dock, a boat lift or a small pond. The 3/4 HP units are the most common choice on Ontario waterfronts, and the 1 HP units cover marinas and multi-slip docks.
Current, wind exposure and depth all change the answer. Send us the dock layout and we will spec it.
-
It does not heat anything. The unit hangs below the surface and drives warmer water up from depth, where water sits a few degrees above freezing all winter. Keeping that water moving prevents the surface from setting.
Because it works by circulation rather than heat, the opening you get depends on mounting angle and depth as much as on horsepower.
-
Not to run one, but a thermostat panel is worth the money. It switches the unit on only below a set water temperature rather than running it continuously through the season, which makes a real difference to winter hydro.
See our Kasco control panels, or ask us which panel matches your horsepower and supply. Electrical work should be completed by a licensed electrician to local code.
-
Indirectly, yes. Winterkill happens when a pond seals under ice and gases from decomposition build up with no way out. Holding an opening lets those gases escape.
On deeper ponds, diffused aeration run through winter does the same job while also circulating the whole column. Tell us the depth and we will advise which is the better fit.
-
Every Kasco de-icer ships with 20 ft of rope for suspension and carries a three-year warranty. Power cords are built from 25 ft up to 200 ft.
Measure from where the unit will hang to the actual outlet, not to the shoreline - the difference is where most people come up short. We can confirm the run before you order.
The Canadian advantage on every order
Authorized Kasco Dealer
Genuine units with full manufacturer warranty, not grey-market imports.
Certified Repair Centre
Factory-trained bench techs rebuilding motors, seals and props in Markham. Send it here, not south of the border.
50+ Years in the Field
We have installed and serviced these systems since 1974. Ask us what actually fails at year eight.
Ships Across Canada
Most orders leave the warehouse in 1-2 business days. No cross-border brokerage surprises.
Built for Canadian Winters
De-icing and freeze-up guidance from a team that works through Ontario winter every year.
A Human Answers
Call and reach someone who has installed the equipment you are about to buy.
Winter & De-Icing Guides
-
De-Icer vs. Bubbler vs. Aerator: What Keeps Water Open in Winter?
De-icers aim open water at docks and lifts; bubblers (diffused air) suit deep ponds and dugouts; aerators are summer tools. Here's how to choose for a Canadian winter.Read More -
Pond Algaecide in Canada: What Is Legal and What Actually Works
Most pond algaecides sold in the US cannot legally be sold or used in Canada. Here is what the Pest Control Products Act actually requires, and the nutrient-management approach that works instead.Read More -
How to Control Eurasian Milfoil in Canadian Lakes and Ponds
Eurasian watermilfoil spreads from fragments, so control means cutting and removing every piece, limiting light with pond dye, and improving overall lake health with aeration — herbicides are heavily restricted in Canada.Read More












